[pdf] Most “sequencers” on the market have been designed to work with screw (or reciprocating) compressors, “positive-displacement” type.. .
Fifteen years ago, I performed a Level 1 audit on a compressed air system with four 800 HP Joy TA centrifugal compressors. See Figure 1 for the system, as found in 2002. Three were running in parallel, with local controls, and one running in a segmented part of. .
Since performance degrades as the inlet valve closes back, 15% in this example project, one might suggest a hybrid system using a screw compressor for trim with the centrifugal. .
Picture two draft-horses, both pulling evenly on the same plow, in parallel. To make this happen, they need to be harnessed correctly,. .
Some load-sharing algorithms only balance the compressors. They don’t turn off a compressor at the point there is sufficient turn-down. This is okay for systems with flat loads. But if demand floats, a master control system able to start and stop, along.
[pdf] When the temperature of the oil measured by the sensor of the temperature control valve is lower than the action value (generally 70 - 85 degrees), the lubricating oil directly returns to the main engine from gas cylinder; when the oil temperature is higher than the action value, the temperature sensor of the temperature control valve is driven by the sleeve to push away the valve core, open the bypass valve, and let the lubricating oil enter the cooler for cooling (the higher the temperature, the larger the bypass valve is opened), and then the cooled lubricating oil to the main engine, so as to control the exhaust temperature of the air compressor during operation.